Comprehensive solutions to monitor treatment effectiveness. Synchronization is the key to effective NIV but can be
difficult to attain in some patients. The new VPAP III ST-A combines time-tested synchronization features with new,
adjustable settings. VPAP III ST-A provides comfortable transitions from breath to breath as well as hospital to home.
* Effective synchronization: The VPAP way Vsync™ and TiControl™—exclusive, time-tested, VPAP features optimize synchronization.
* Vsync automatic leak compensation algorithm:
* Monitors and compensates for leak
* Automatically maintains reliable trigger and cycle thresholds
* Now offers adjustable trigger and cycle thresholds—a simple choice of “low,” “medium,” or “high.”
* TiControl (Inspiratory Time Control): Allows time limits to be set at either side of the patient’s ideal spontaneous inspiratory time
* Can help prevent late cycling, as seen in large peak conditions and in patients with obstructive disorders; or early cycling, as sometimes seen in patients with restrictive disorders.
* Extra flexibility and confidence: Range of alarms and modes
* Adjustable alarms: To assess adequacy of treatment—Low Pressure, High Pressure, and Low Minute Ventilation alarms
* New Non-vented Circuit alarm—alerts to non-vented mask connection issues
Standard fixed alarms
* Power Fail, Over Pressure, Over Use, Fault, and Mask Off. Range of modes for flexible therapy
Range of Modes
1. CPAP
2. Spontaneous
3. Spontaneous-Timed
4. Timed
Technical Specifications
* Dynamic pressure characteristics
* IPAP: 3 cm H20 to 30 cm H20 (measured at the end of standard 2m air tubing)
* EPAP: 3 cm H20 to 25 cm H20 (measured at the end of standard 2m air tubing)
* Pressure range for PN 24117 is:
* IPAP 2 cm H20 to 30 cm H20
* EPAP 2 cm H20 to 25 cm H20
* IPAP Max range (0.1–4 sec)
* IPAP Min range (0.1–IPAP Max)
* Rise Time range (Min, 150–900 msec)
* Respiratory rate range (5–30 BPM, 1 BPM increment)
* Dimensions (L x W x H) 270 mm x 230 mm x 141 mm
* Weight (2.3kg)
* Air outlet 22mm taper, compatible with EN 1281–1:1997
* Anesthetic & Respiratory Equipment – Conical Connectors
* Pressure measurement - Internally mounted pressure transducer
* Flow measurement - Internally mounted flow transducer
* Power supply - AC 100-240V, 2.2A ~50–60Hz
* DC via 12V to 24V converter: 4A into converter, 2A into device
* Housing construction - Flame-retardant engineering thermoplastic
* Air Filter - Two-layered, powder-bonded, polyester non-woven fiber
* Air Tubing - Flexible plastic, 2m or 3m length
The FDA does require us to have a prescription on file to purchase this equipment. Please fax or email us a valid prescription if you have not provided us with one for your sleep apnea equipment.